Show simple item record

dc.contributor.authorCarneiro, Ariê
dc.contributor.authorWroclawski, Marcelo Langer
dc.contributor.authorPeixoto, Guilherme Andrade
dc.contributor.authorDoyun, Jonathan
dc.contributor.authorMoran, Natasha Kouvaleski Saviano
dc.contributor.authorChen, Felipe Ko
dc.contributor.authorSatkunas, Henrique Nelson
dc.contributor.authorCampos, José Roberto Augusto
dc.contributor.authorGarcia, Alides Maria Mendes Rasabone
dc.contributor.authorMonga, Manoj
dc.contributor.authorLemos, Gustavo Caserta
dc.date.accessioned2024-11-08T14:53:23Z
dc.date.available2024-11-08T14:53:23Z
dc.date.issued2020
dc.identifier.issn1756-2872
dc.identifier.urihttps://openalex.org/W2999310701
dc.identifier.urihttps://doi.org/10.1177/1756287219889496
dc.identifier.urihttps://journals.sagepub.com/doi/pdf/10.1177/1756287219889496
dc.identifier.urihttps://repositorio.maua.br/handle/MAUA/1801
dc.description.abstractBackground: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. Methods: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch ® (Model A), 100% Silicone Rusch ® (Model B) and X-Flow Coloplast ® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. Results: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. Conclusion: Precise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications.en
dc.languageInglêspt_BR
dc.publisherSAGE Publishingen
dc.relation.ispartofTherapeutic Advances in Urology
dc.rightsAcesso Aberto
dc.sourceOpenAlexen
dc.subjectStandardisation of Lower Urinary Tract Functionen
dc.subjectEpidemiology and Treatment of Urinary Tract Infectionsen
dc.subjectPelvic Floor Disordersen
dc.subjectStandardisation of Lower Urinary Tract Functionen
dc.subjectUrologyen
dc.subjectMedicineen
dc.subjectHealth Sciencesen
dc.subjectUrinary Incontinenceen
dc.subjectPort (circuit theory)en
dc.subjectMedicineen
dc.subjectCatheteren
dc.subjectDrainageen
dc.subjectIrrigationen
dc.subjectPort (circuit theory)en
dc.subjectSurgeryen
dc.subjectMechanical engineeringen
dc.subjectEngineeringen
dc.subjectEcologyen
dc.subjectBiologyen
dc.subjectAcesso Abertopt_BR
dc.titleSame sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage propertiesen
dc.typeArtigo de Periódicopt_BR
dc.identifier.doihttps://doi.org/10.1177/1756287219889496
dc.description.affiliationDepartment of Urology, Hospital Israelita Albert Einstein, São Paulo, SP - 06455-010, Brazilpt_BR
dc.description.affiliationFaculdade de Medicina do ABC, São André, Brazilpt_BR
dc.description.affiliationHospital Israelita Albert Einstein, São Paulo, Brazilpt_BR
dc.description.affiliationFaculdade de Medicina do ABC, São André, Brazilpt_BR
dc.description.affiliationFaculdade de Medicina do ABC, São André, Brazilpt_BR
dc.description.affiliationHospital Israelita Albert Einstein, São Paulo, Brazilpt_BR
dc.description.affiliationFaculdade de Medicina do ABC, São André, Brazilpt_BR
dc.description.affiliationFaculdade de Medicina do ABC, São André, Brazilpt_BR
dc.description.affiliationMauá Technology Institute, São Caetano do Sul, Brazilpt_BR
dc.description.affiliationMauá Technology Institute, São Caetano do Sul, Brazilpt_BR
dc.description.affiliationHospital Israelita Albert Einstein, São Paulo, Brazilpt_BR
dc.description.affiliationCleveland Clinic, Cleveland, OH, USApt_BR
dc.description.affiliationHospital Israelita Albert Einstein, São Paulo, Brazilpt_BR
dc.contributor.orcidhttps://orcid.org/0000-0002-0152-0513
dc.contributor.orcidhttps://orcid.org/0000-0001-6835-9085
dc.contributor.orcidhttps://orcid.org/0000-0002-9022-1880
dc.contributor.orcidhttps://orcid.org/0000-0002-7262-9057
dc.contributor.orcidhttps://orcid.org/0000-0001-8818-4964
dc.citation.epage175628721988949
dc.citation.spage175628721988949
dc.citation.volume12
dc.identifier.openalexhttps://openalex.org/W2999310701


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record