Repositório Institucional

    • Login
    View Item 
    •   DSpace Home
    • Engenharia
    • Artigos de Periódicos
    • View Item
    •   DSpace Home
    • Engenharia
    • Artigos de Periódicos
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of DSpaceCommunities & CollectionsAuthorsSubjectsThis CollectionAuthorsSubjects

    My Account

    LoginRegister

    Environmental Protection with HDPE Geomembranes in Mining Facility Constructions

    View/Open
    Environmental Protection with HDPE Geomembranes in Mining Facility Constructions.pdf (14.35Mb)
    xmlui.dri2xhtml.METS-1.0.item-type
    Artigo de Periódico
    Date
    2021
    Author
    Lavoie, Fernando Luiz
    Kobelnik, Marcelo
    Valentin, Clever Aparecido
    Tirelli, Érica Fernanda da Silva
    Lopes, Maria de Lurdes
    Silva, Jefferson Lins da
    Metadata
    Show full item record
    Abstract
    The present work evaluated two high-density polyethylene (HDPE) geomembranes exhumed from mining facility constructions in Brazil. The MIN sample was exhumed from a pond for water use for the iron ore process after 7.92 years of exposure. The MIN2 sample was exhumed from a spillway channel of a ferronickel tailing dam after 10.08 years of service. The physical evaluations showed high depletion for antioxidants that work in the temperature range of 200 °C. The samples presented brittle tensile behavior and had similar behaviors between stress cracking and tensile. Low tensile elongation values and low-stress crack resistance were noted. The MIN2 sample presented a higher melt flow index (MFI) value and lower stress crack resistance. Thermogravimetric curves (TG) under synthetic air purge gas evaluation showed that both samples presented a similar behavior during the evaluation but had several mass losses. The results showed that exothermic and endothermic events occurred with loss of mass and showed no combustion events in the differential thermal analysis (DTA) curve evaluation. Differential scanning calorimetry (DSC) analysis showed no changes in the samples’ behavior. Thus, the results of tensile, stress cracking, and viscosity properties can demonstrate that changes in polymer structure occurred after field exposures. © 2021 by the authors.
    1. durability
    2. geomembrane
    3. high-density polyethylene
    4. mining facilities construction
    5. thermal analysis
    URI
    https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146056678&doi=10.3390%2fconstrmater1020009&partnerID=40&md5=6a000e8cd2c1556c80faf6e697c308d7
    https://repositorio.maua.br/handle/MAUA/1422
    Collections
    • Artigos de Periódicos

    Contact Us | Send Feedback
    Instituto Mauá de Tecnologia - Todos os direitos reservados 2021
     

     


    Contact Us | Send Feedback
    Instituto Mauá de Tecnologia - Todos os direitos reservados 2021